Knowledge Center · Thermocouple colour codes

Thermocouple colour codes — IEC 60584-3 and ANSI MC 96.1

Thermocouple colour codes identify the thermocouple type (B, E, J, K, N, R, S or T) by the insulation colour of each conductor. The international standard IEC 60584-3 uses a white negative conductor for all types, while the American standard ANSI MC 96.1 uses a red negative conductor. The same colour can mean different things under different standards, so always identify the standard before connecting.

IEC 60584-3 — the international colour code

IEC 60584-3 specifies requirements, tolerances and identification for thermocouple extension and compensating cables, including their colour identification — also written thermocouple color codes in American English. The negative conductor is always white; the positive conductor and the outer sheath carry the type colour.

IEC 60584-3 colour codes by thermocouple type
TypeConductor pair (+ / −)Positive (+)Negative (−)Sheath
KNiCr / NiAlGreenWhiteGreen
JFe / CuNiBlackWhiteBlack
TCu / CuNiBrownWhiteBrown
ENiCr / CuNiVioletWhiteViolet
NNiCr / NiSiPinkWhitePink
S / RS: Pt-10%Rh / Pt
R: Pt-13%Rh / Pt
OrangeWhiteOrange
BPt-30%Rh / Pt-6%RhGreyWhiteGrey

Thermocouple wires intended for high temperatures normally have sheaths which cannot be coloured. A coloured identification fibre is sometimes integrated into the sheath instead.

ANSI MC 96.1 — the American colour code

Under ANSI MC 96.1 the negative conductor is always red. The positive conductor carries the type colour. Extension-grade wire uses a type-coloured jacket, while thermocouple-grade wire has a brown overall jacket for every type.

ANSI MC 96.1 colour codes by thermocouple type
TypePositive (+)Negative (−)Extension-grade jacket
KYellowRedYellow
JWhiteRedBlack
TBlueRedBlue
EVioletRedViolet
NOrangeRedOrange
S / RBlackRedGreen
BGreyRedGrey

Types R, S and B are normally supplied as extension or compensating cable only.

Older national standards — DIN, BS, NF C and JIS

Before IEC 60584-3, most industrial countries had their own colour codes. Equipment wired to these standards is still in service worldwide, so the older codes remain relevant when extending or replacing sensors on existing installations. The table below gives the positive conductor, the negative conductor and the sheath for each type under each standard.

Older national colour codes — positive / negative / sheath per type
TypeDIN 43714 (Germany — replaced by IEC)BS 1843 (UK — replaced by IEC)NF C 42-324 (France — replaced by IEC)JIS C 1610 (Japan)
K + Red− GreenSheath Green + Brown− BlueSheath Red + Yellow− VioletSheath Yellow + Red− WhiteSheath Blue
J + Red− BlueSheath Blue + Yellow− BlueSheath Black + Yellow− BlackSheath Black + Red− WhiteSheath Yellow
T + Red− BrownSheath Brown + White− BlueSheath Blue + Yellow− BlueSheath Blue + Red− WhiteSheath Brown
E + Red− BlackSheath Black + Brown− BlueSheath Brown + Yellow− VioletSheath Violet + Red− WhiteSheath Violet
N Not defined + Orange− BlueSheath Orange Not defined Not defined
S / R + Red− WhiteSheath White + White− BlueSheath Green + Yellow− GreenSheath Green + Red− WhiteSheath Black
B + Red− GreySheath Grey Not defined Not defined + Red− GreySheath Grey
Before you connect

Red means the opposite thing in America and Japan: under ANSI MC 96.1 the red conductor is always negative, while under JIS C 1610 the red conductor is always positive. Identify the standard before you wire a thermocouple, or the polarity will be reversed.

Colour codes by thermocouple type

The tables above are organised by standard. This section turns them around: one block per thermocouple type, with the colours from every standard in one place — for when you know the type and need its colours, or you have an unknown cable and a colour to match.

Jump to type: K · J · T · E · N · S · R · B

Type K colour codes

A type K thermocouple (NiCr / NiAl) has a green positive conductor, a white negative conductor and a green sheath under IEC 60584-3 — and a yellow positive, a red negative and a yellow extension-grade jacket under ANSI MC 96.1.

Type K colour codes by standard
StandardPositive (+)Negative (−)Sheath / jacket
IEC 60584-3GreenWhiteGreen
ANSI MC 96.1YellowRedYellow
DIN 43714RedGreenGreen
BS 1843BrownBlueRed
NF C 42-324YellowVioletYellow
JIS C 1610RedWhiteBlue

Type J colour codes

A type J thermocouple (Fe / CuNi) has a black positive conductor, a white negative conductor and a black sheath under IEC 60584-3 — and a white positive, a red negative and a black extension-grade jacket under ANSI MC 96.1.

Type J colour codes by standard
StandardPositive (+)Negative (−)Sheath / jacket
IEC 60584-3BlackWhiteBlack
ANSI MC 96.1WhiteRedBlack
DIN 43714RedBlueBlue
BS 1843YellowBlueBlack
NF C 42-324YellowBlackBlack
JIS C 1610RedWhiteYellow

Type T colour codes

A type T thermocouple (Cu / CuNi) has a brown positive conductor, a white negative conductor and a brown sheath under IEC 60584-3 — and a blue positive, a red negative and a blue extension-grade jacket under ANSI MC 96.1.

Type T colour codes by standard
StandardPositive (+)Negative (−)Sheath / jacket
IEC 60584-3BrownWhiteBrown
ANSI MC 96.1BlueRedBlue
DIN 43714RedBrownBrown
BS 1843WhiteBlueBlue
NF C 42-324YellowBlueBlue
JIS C 1610RedWhiteBrown

Type E colour codes

A type E thermocouple (NiCr / CuNi) has a violet positive conductor, a white negative conductor and a violet sheath under IEC 60584-3 — and a violet positive, a red negative and a violet extension-grade jacket under ANSI MC 96.1.

Type E colour codes by standard
StandardPositive (+)Negative (−)Sheath / jacket
IEC 60584-3VioletWhiteViolet
ANSI MC 96.1VioletRedViolet
DIN 43714RedBlackBlack
BS 1843BrownBlueBrown
NF C 42-324YellowVioletViolet
JIS C 1610RedWhiteViolet

Type N colour codes

A type N thermocouple (NiCr / NiSi) has a pink positive conductor, a white negative conductor and a pink sheath under IEC 60584-3 — and an orange positive, a red negative and an orange extension-grade jacket under ANSI MC 96.1.

Type N colour codes by standard
StandardPositive (+)Negative (−)Sheath / jacket
IEC 60584-3PinkWhitePink
ANSI MC 96.1OrangeRedOrange
DIN 43714Not defined
BS 1843OrangeBlueOrange
NF C 42-324Not defined
JIS C 1610Not defined

Type S and type R colour codes

Type S (Pt-10%Rh / Pt) and type R (Pt-13%Rh / Pt) share the same colour codes: an orange positive conductor, a white negative conductor and an orange sheath under IEC 60584-3 — and a black positive, a red negative and a green extension-grade jacket under ANSI MC 96.1.

Type S and type R colour codes by standard
StandardPositive (+)Negative (−)Sheath / jacket
IEC 60584-3OrangeWhiteOrange
ANSI MC 96.1BlackRedGreen
DIN 43714RedWhiteWhite
BS 1843WhiteBlueGreen
NF C 42-324YellowGreenGreen
JIS C 1610RedWhiteBlack

Type B colour codes

A type B thermocouple (Pt-30%Rh / Pt-6%Rh) has a grey positive conductor, a white negative conductor and a grey sheath under IEC 60584-3 — and a grey positive, a red negative and a grey extension-grade jacket under ANSI MC 96.1.

Type B colour codes by standard
StandardPositive (+)Negative (−)Sheath / jacket
IEC 60584-3GreyWhiteGrey
ANSI MC 96.1GreyRedGrey
DIN 43714RedGreyGrey
BS 1843Not defined
NF C 42-324Not defined
JIS C 1610RedGreyGrey

Extension wires and compensating cables — KX versus KCA

Extension wires are made from the same alloys as the corresponding thermocouple and are marked with the letter X — KX for type K, for example. Their tolerances equal thermocouple class 1 or class 2 to IEC 60584 within a limited temperature range, typically −25 to 200 °C.

Compensating cables are produced from substitute alloys and are marked with the letter C plus a letter identifying the alloy — for example KCA, SCA or SCB. Compensating cables carry the same thermoelectric behaviour over a defined ambient range and cover class 2 duty within it — KCA, for instance, from 0 to 150 °C. Where class 1 tolerances are required, choose extension wire in the thermocouple’s own alloys.

The cable sheathing can limit the range further. PVC sheathing, for example, limits the ambient temperature at the cable location to below 100 °C. Connectors should carry the same colour marking as the corresponding cable.

Frequently asked questions

What colour is type K thermocouple wire?

Under IEC 60584-3, type K has a green positive conductor, a white negative conductor and a green sheath. Under ANSI MC 96.1, type K has a yellow positive conductor and a red negative conductor, with a yellow extension-grade jacket.

Why do IEC and ANSI thermocouple colours differ?

They were developed by different standards bodies. IEC 60584-3 is the international standard and uses white for the negative conductor; ANSI MC 96.1 is the American standard and uses red for the negative conductor. The same colour can indicate opposite polarity under different standards, so the standard must be identified before wiring.

Is red positive or negative on a thermocouple?

It depends on the standard. Under ANSI MC 96.1 red is always the negative conductor. Under JIS C 1610 red is always the positive conductor. IEC 60584-3 does not use red at all — its negative conductor is white for every type.

What is the difference between extension wire and compensating cable?

Extension wire (marked X, for example KX) uses the same alloys as the thermocouple and can meet class 1 tolerances. Compensating cable (marked C, for example KCA) uses substitute alloys, qualifies only for class 2 tolerances and has a narrower ambient temperature range.

What do the thermocouple letters B, E, J, K, N, R, S and T mean?

Each letter identifies a standardised conductor pair — type K is NiCr/NiAl and type J is Fe/CuNi, for example — with tolerances defined in IEC 60584. The letter determines the temperature range, the output signal and the colour code.

How do I identify the thermocouple type from the wire colours?

Start with the negative conductor: white on every type means IEC 60584-3, and red means ANSI MC 96.1. A red positive conductor points to the older DIN 43714 or the Japanese JIS C 1610 codes instead. Then match the type colour in the per-type section — under IEC 60584-3 the positive conductor and the sheath carry it, for example green for type K.

Related

This information is provided as a service and for information purposes only. While we have made every effort to keep the information as accurate as possible, the page may contain errors or omissions for which we disclaim any and all liability.